ZQGQ Self-resetting overvoltage and undervoltag

• ZQGQ self-reset overvoltage/undervoltage delay protector is a new generation product developed by our company according to market demand.The protector is reasonably designed and assembled with imported components and domestic famous brand components, and adoptsa dvanced technology and manufacturing means. The product can quickly and reliably cut off the power supply and protect household appliances under high voltage impact and undervoltage. When the voltage returns to the normal value, it can automatically connect the circuit and restore the power supply after a delay.

Product overview

• ZQGQ self-reset overvoltage/undervoltage delay protector is a new generation product developed by our company according to market demand.The protector is reasonably designed and assembled with imported components and domestic famous brand components, and adoptsa dvanced technology and manufacturing means. The product can quickly and reliably cut off the power supply and protect household appliances under high voltage impact and undervoltage. When the voltage returns to the normal value, it can automatically connect the circuit and restore the power supply after a delay. It can effectively protect the impact of electrical appliances being powered on at the moment of power supply. All functions are automatic, without the need for special personnel to operate, and double-light indication is selected.
• Power indicator: green.
• Protection indication: red.

 

Model meaning

ZQ GQ 63 1P 63A

ZQ -Name of the company
GQ -Product model
63 -Shell frame grade
1P -Number of poles
63A -Rated current

Main technical parameters

Specifications Rated current
In.A
Rated yoltage
Ue.V
Rated frequency
f.H.Z
Overvoltage starting
value V
Normal pressure
ecovery value V
Undervoltage
starting value V
ZQGQ
two-phase overvoltage
and undervoltage
25、32
40、50
63、80
100、125
230AC 50 265±5 240~260 175±5
ZQGQ
three-phase four-wire
overvoltage+phase loss
400AC 460±15 420~440 300±15

 

Specifications Normal pressure
recovery value V
Recovery delay
time S
Self power
consumption W
Mechanical
(electrical)life
ZQGQ
two-phase overvoltage
and undervoltage
190±5 ≤60s <1 100,000 times
ZQGQ
three-phase overvoltage
and undervoltage+phase loss
Three-phase four- wire overvoltage and
undervoltage+phase loss
335±10 <2