CJX2 Ac contactor

• CJX2 series AC contactors (hereinafter referred to as contactors) are applicable to circuits with AC50Hz or 60Hz, working voltage up to 660V, rated working voltage up to 380V and working current up to 95A under AC-3 use category, for remote connection and disconnection of circuits and frequent starting and control of AC motors. Contactors can also be assembled into building block auxiliary contact group, air delay head, mechanical interlocking mechanism and other components to form delay contactors Reversible contactor and star-delta starter can be directly inserted and installed with thermal relay to form electromagnetic starter.

Product overview

• CJX2 series AC contactors (hereinafter referred to as contactors) are applicable to circuits with AC50Hz or 60Hz, working voltage up to 660V, rated working voltage up to 380V and working current up to 95A under AC-3 use category, for remote connection and disconnection of circuits and frequent starting and control of AC motors. Contactors can also be assembled into building block auxiliary contact group, air delay head, mechanical interlocking mechanism and other components to form delay contactors Reversible contactor and star-delta starter can be directly inserted and installed with thermal relay to form electromagnetic starter.
• Compliance standards: IEC60947-4-1,GB/T 14048.4.

 

Model meaning

CJX -2 -D □ □ □ □

CJX -AC contactor
2 -Design serial number
D -Series code
□ -Rated working current
□ -Number of normally open auxiliary contacts
□ -Number of normally closed auxiliary contacts
□ -See table for coil voltage value code

 

Main technical parameters

Model CJX2
-D09
CJX2
-D12
CJX2
-D18
CJX2
-D25
CJX2
-D32
CJX2
-D40
CJX2
-D50
CJX2
-D63
CJX2
-D80
CJX2
-D95
Rated insulation
voltage (V)
660 660 660 660 660 660 660 660 660 660
Agreed heating current It(V) 25 25 32 40 50 60 80 80 125 125
Rated working power 380VAC3 9 12 16 25 32 40 50 63 80 95
Control
power (kW)
220V 2.2 3 4 5.5 7.5 11 15 18.5 22 25
380V 4 5.5 7.5 11 15 18.5 22 30 37 45
415V 4 5.5 9 11 15 22 25 37 45 45
440V 4 5.5 9 11 15 22 30 37 45 45
660V 5.5 7.5 10 15 18.5 30 33 37 45 45
Remarks Installation method:1.Install with two screws.2.35mm guide rail installation.
1.Install the three screws.2.75mm or 35mm

Note:
• 3P:three pairs of normally open main contacts N0:one pair of normally open auxiliary contacts.NC:a pair of normally closed auxiliary contacts
• 0901-3201 1NC 40-95 1NO+1NC
• 0910-3210 1NC

 

Coil parameters

Model CJX2
-D09
CJX2
-D12
CJX2
-D18
CJX2
-D25
CJX2
-D32
CJX2
-D40
CJX2
-D50
CJX2
-D63
CJX2
-D80
CJX2
-D95
Rated insulation 660 660 660 660 660 660 660 660 660 660
Agreed heating 25 25 32 40 50 60 80 80 125 125
Control
power(kW
220V 2.2 3 4 5.5 7.5 11 15 18.5 22 25
380V 4 5.5 7.5 11 15 18.5 22 30 37 45
415V 4 5.5 9 11 15 22 25 37 45 45
440V 4 5.5 9 11 15 22 30 37 45 45
660V 5.5 7.5 10 15 18.5 30 33 37 45 45